The PR-243 incorporates sophisticated integrated circuits and a 100% solid state piezoresistive silicon sensor to not only provide a high-level, fully conditioned, and temperature-compensated output, but also to offer up to three field selectable pressure ranges in one unit. The field selectable feature eliminates costly inefficiencies by providing a single unit which can be configured to cover all the pressure ranges for a particular application: for instance, 5, 10 and 20 PSIG in one unit. Two industry standard output versions are available: 4 to 20mA 2-wire loop or field selectable 0 to 5 VDC/0 to 10 VDC. A wide 12 to 40 VDC or 12 to 35 VAC unregulated supply voltage and a broad 0°F to 180°F compensated temperature range ensures compatibility mounting bracket, fully temperature-compensated NIST traceable accuracy and a liberal two year warranty are some of the features which make the PR-243 the industry’s most reliable, rugged, and economical pressure transducer.

The PR-243 sensing element is a 100% solid state piezoresistive silicon chip featuring low hysteresis, excellent repeatability, and long-term stability. The chip is connected as a four-active-element bridge circuit for optimum linearity and sensitivity. Signal conditioning and temperature compensation are performed by industrial quality, state-of-the-art integrated circuits to provide an accurate, linear, and high level output that requires no additional signal conditioning. The PR-243 incorporates sophisticated integrated circuits to not only provide a high level, fully conditioned and temperature-compensated output, but also to offer field selectable flexibility which was unheard of in the industry.

The PR-243 offers up to three field selectable pressure ranges in one unit. In this way, a customer does not need to know the exact pressure range prior to selection. A unit can be field configured for the desired pressure range in the field. With fixed range units, in case of engineering error or incorrect selection, the only solution is expensive field recalibration or time-consuming product exchange or replacement. Similarly, numerous units have to be kept in stock as spares to cover all ranges in case of field failure. The PR-243 with the field selectable pressure range feature eliminates above mentioned costly inefficiencies. A single unit can be configured to cover all the pressure ranges in a particular application thereby eliminating any possibility of incorrect range selection. Additionally, one unit can be kept in stock and, in the event of a failure, it can be field configured thereby eliminating the need to stock numerous fixed range units.

On VDC output units, two additional field selectable options are available: dual outputs 0 to 5 or 0to 10 VDC, and dual unregulated supply voltages 12 to 35 VAC or 12 to 40 VDC. By merely moving a shorting plug, one can select the desired output for the specific application. As far as supply voltage is concerned, the unit automatically configures for AC or DC and no field selection is necessary. Another feature is that the output is fully protected from short circuit to ground, or if the supply voltage is applied by mistake to the output. Past experience demonstrates that field related wiring problems do occur. Instead of denying this fact, the protection circuit is designed in to ensure trouble-free start up. The VDC output unit is also designed to handle low impedance circuits. In fact, the unit can drive up to 1K ohms minimum. In this way, multiple controllers, indicators, or other devices can be paralleled to the output without performance degradation.

The mA output units can function over a wide unregulated supply voltage range: 12 to 40 VDC without any affect on calibration or performance. The unit has reverse polarity protection built in. As a result, it is next to impossible to damage the unit by mis-wiring. By using sophisticated low drop-out voltage regulators and CMOS integrated circuits, the mA output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 400 ohms. At 40 VDC, the unit is capable of handling up to a 3000 ohm load. In this way, the output loop can be tied in series to multiple controllers, indicators, and other devices without degrading the performance.

Automated NIST traceable pressure controllers and precision pressure sensors are utilized to calibrate and certify the PR-243. Calibration data on each unit is archived digitally for SPC and QC purposes. All automated calibration systems are networked and data is available online to numerous individuals at the same time. In this way, extremely high standards of quality and calibration integrity are maintained. Each unit is individually temperature- compensated in an environmental chamber. The temperature compensation data is also digitized and archived for future reference purposes. Compensating each unit individually ensures that published specifications are adhered to.

The PR-243 incorporates a rugged NEMA-4 (IP-65) fully gasketed, dustproof and splashproof enclosure. The enclosure has an external mounting bracket to facilitate field installation. A ½" (.875"/22.25 mm diameter) knock-out for conduit connection is also provided. A liquid tight cable connector is also supplied if the unit is not being hard wired. Once installed, the enclosure maintains its environmental rating and protects the electronics and the sensing element from condensation, corrosive contaminants and other environmental pollutants. The unit also has additional features for ease of installation including unpluggable terminal block, easily accessible zero and span trimmers, and conveniently located shorting plugs for field selection.